Dell PowerVault ME5012 and ME5024 storage systems in Tashkent: FC, iSCSI, SAS — configurations and prices
Updated
In brief. Dell PowerVault ME5 in Tashkent — configurations from an ME5012 with two Fibre Channel controllers without drives to an ME5012 SAS fitted with twelve 16 TB drives; price on request (Servix catalog, November 2026). The ME5012 has twelve 3.5-inch bays for capacity, the ME5024 has twenty-four 2.5-inch bays for performance. The interface is chosen based on the infrastructure: FC where a fabric already exists, iSCSI at 10 and 25 GbE on a regular network, SAS for direct connection of two to four servers without a switch.
Request a storage system calculation for your task → — send us the data volume, the number of servers and redundancy requirements, and an engineer will put together a configuration with drives and shelves.
Quick links: ME5012 or ME5024 · FC, iSCSI or SAS · ME5012 configurations · ME5024 configurations · expansion shelves · how to calculate capacity · typical tasks · warranty and lead times · questions and answers
ME5012 or ME5024: capacity versus performance
Both models are 2U dual-controller arrays with identical electronics and an identical feature set. The only difference is the drive enclosure, and it determines everything else.
Parameter | ME5012 | ME5024 |
|---|---|---|
Bays | 12 × 3,5" LFF | 24 × 2,5" SFF |
Typical drive | SAS 7.2k, 8–20 TB | SAS 10k, 1.2–2.4 TB; SAS SSD 1.92–3.84 TB |
Strength | total terabytes per rack unit and per unit of cost | number of spindles and IOPS, room for all-flash |
Typical workload | file archive, backup, video surveillance | virtualization, 1C and DBMS, mixed workloads |
Catalog price | price on request | price on request |
The rule is simple: if the task is measured in terabytes, take the ME5012; if in operations per second, the ME5024. A mixed option also works: an ME5024 with several SSDs for hot data and an ME412 shelf with large drives for cold data.
FC, iSCSI or SAS: which interface to choose
This decision is made not by preference but by what is already in the server room. The interface cannot be changed after purchase without replacing the controllers, so it is chosen first.
Interface | When it is chosen | Server-side requirements | Catalog example | Price |
|---|---|---|---|---|
Fibre Channel 16/32G | an FC fabric and switches already exist, latency is critical | HBA in each server, two FC switches | ME5012 FC 12LFF without drives | price on request |
iSCSI 10/25 GbE | regular Ethernet network, growth needed without a separate fabric | 10/25G network adapters and separate VLANs or switches | ME5012 iSCSI 12LFF with 12 × 2.4 TB SAS 10k | price on request |
SAS 12G | two to four servers nearby, no switches needed | SAS HBA in each server, cables up to 10 m | ME5024 SAS 24SFF without drives | price on request |
SAS is the cheapest entry: no switches, no port licenses, but the number of hosts is limited by the number of controller ports. iSCSI is a compromise: the same network as the servers, and at 25 GbE the performance is enough for almost everyone. FC is chosen where the fabric is already built and is easier to expand than to introduce a second connection type.
ME5012 configurations: 12 3.5-inch drives
- ME5012 FC 12LFF — price on request. A chassis with two Fibre Channel controllers, 8 GB cache, without drives. A base item: drives are selected separately for the task.
- ME5012 iSCSI 12LFF — price on request. Fitted with twelve 2.4 TB SAS 10k drives: about 28 TB of raw capacity, a sensible compromise between speed and volume.
- ME5012 SAS 12LFF — price on request. Twelve 16 TB drives, 192 TB of raw capacity, direct connection to servers.
Note: the price difference between these items is almost entirely the cost of drives, not controllers. An empty chassis with any interface costs about the same; beyond that you pay for capacity.
ME5024 configurations: 24 2.5-inch drives
- ME5024 SAS 24SFF — price on request. A chassis with 8 GB cache without drives, direct connection of up to four servers.
- ME5024 FC 24SFF — price on request. With six 1.92 TB SAS Read Intensive SSDs: a starter all-flash volume for virtualization with eighteen bays to spare.
- ME5024 iSCSI 24SFF — price on request. The same drive set, 10/25 GbE interface — the most common choice for a virtualization cluster on a regular network.
Twenty-four bays give room for growth: you can start with six to eight drives and add more as needed without stopping the array.
Expansion shelves
When bays run out, drive shelves are connected to the array via SAS. The data stays under the management of the same controllers; a separate storage system is not needed.
- PowerVault ME412 — 93,000,000 UZS. A shelf for twelve 3.5-inch drives, supplied with two 20 TB drives. The native shelf for the ME5 line.
- PowerVault MD1400 — 33,000,000 UZS. Twelve 3.5-inch bays, without drives. A previous-generation shelf, an inexpensive way to add capacity where it is compatible — this is verified for the specific configuration.
How to calculate capacity: drives, RAID, hot spares
Raw capacity and usable capacity are different numbers, and the difference is larger than expected. Calculate as follows.
- Protection level. On drives of 8 TB and larger, RAID 5 is not used: a rebuild takes a day or more, and a second failure in that window kills the group. RAID 6 or ADAPT is used — Dell's distributed scheme where spare capacity is spread across all drives and the rebuild is noticeably faster.
- Capacity example. Twelve 16 TB drives in RAID 6 give about 160 TB of raw usable capacity before formatting, minus the reserve for a hot spare. Realistically, plan for 140–150 TB and do not fill the array beyond 80%.
- Performance example. Six 1.92 TB SSDs in RAID 6 give about 7.7 TB of usable capacity. Little in terabytes, but enough for the system disks of three dozen virtual machines and a 1C database.
- Hot spares. One spare drive per group is the minimum, two is the norm for an array located in a branch that an engineer cannot reach on the same day.
A detailed analysis of levels is in the guide RAID 5, 6 or 10: what to choose for a storage system. How to choose between SAN, NAS and all-flash in general — here, a general overview of storage system classes — in this article.
What tasks the ME5 is chosen for
- Virtualization cluster of 2–4 hosts. The classic scenario: two or three PowerEdge servers and a shared volume for virtual machines so that live migration and high availability work. Interface — iSCSI 25 GbE, or SAS if there are no more than four servers.
- 1C and databases. ME5024 with SSDs for logs and the database. Here latency matters more than terabytes, so an SFF chassis is chosen and the number of drives in the group is not skimped on.
- Backup repository. ME5012 with large SAS 7.2k drives. Cheap capacity, sequential writes; for this task RAID 6 is mandatory.
- Video surveillance. The same ME5012, but designed for continuous recording: calculate camera bitrate and archive depth, not just total terabytes.
Warranty, lead times and what is included in the delivery
Servix engineers calculate the configuration free of charge: we select the chassis, interface, drives and shelves for your volume and load profile, and check compatibility with your installed servers and switches. The delivery includes the array with two controllers and power supplies, rails and cables according to the specification; drives are separate items. We work by bank transfer with VAT, prepare specifications for tenders and deliver across Uzbekistan. Made to order — usually 2–3 weeks, the exact lead time is stated in the invoice.
Related sections: all storage systems, Dell storage systems, Dell catalog, PowerEdge servers and drives for servers and storage systems. Server configurations for the array are on the page How to choose a Dell PowerEdge.
Questions and answers
How much does a Dell PowerVault ME5 storage system cost in Tashkent?
All ME5012 and ME5024 configurations — both chassis without drives and fully fitted ones — are currently on request (Servix catalog, November 2026): the price depends on the interface, type and capacity of the drives.
How does the ME5012 differ from the ME5024?
Only in the drive enclosure: the ME5012 has twelve 3.5-inch bays for large drives and capacity, the ME5024 has twenty-four 2.5-inch bays for speed and spindle count. Controllers, cache and functionality are identical.
Which interface to choose: FC, iSCSI or SAS?
FC — if a fabric already exists. iSCSI 10/25 GbE — if you want to stay on a regular Ethernet network and keep growing. SAS — if there are two to four servers in the same rack: it is the cheapest option, but scaling is limited by the controller ports.
How many drives are needed and which RAID?
On drives of 8 TB and larger, use RAID 6 or ADAPT, not RAID 5: a rebuild takes more than a day. Plan for one or two hot spares and do not fill the array beyond 80% of usable capacity.
Can the array be expanded later?
Yes, with SAS drive shelves: the ME412 for twelve 3.5-inch drives for 93,000,000 UZS connects to the same controllers; a separate storage system is not needed. Drives inside the chassis can also be added as you grow.
How soon can you deliver?
Made to order — usually 2–3 weeks, including configurations with a specific set of drives and shelves; the manager states the exact lead time together with the price.
Sources
Other Servix collections
- Server configurations and prices
- Server for 1C: configurations and prices
- How to choose a Dell PowerEdge
- HPE ProLiant Gen11: configurations and prices
- FortiGate by number of employees
- HPE MSA 2060 and 2062 storage systems
- Aruba Instant On for the office
- Network adapters, transceivers and DAC
- Xeon and EPYC server processors
- Drives and RAID controllers
- Server for video surveillance
- Dell PowerVault reference guide
- RAID controller reference guide
- HPE MSA reference guide
- Server for virtualization
- File server and backup