HPE MSA: what 1060, 2060 and 2062 mean — generations, expansion shelves, slot numbering and drives
Updated
In brief. The MSA name encodes the class, interface and drive cage. 1060 — the entry model, 2060 — the main one, 2062 — the same 2060 but with two SSDs included for automated tiered storage. Next comes the server interface — FC, iSCSI or SAS, and the drive cage: 12LFF — twelve 3.5-inch drives, 24SFF — twenty-four 2.5-inch drives. In the Servix catalog MSA 2060 SAS 12LFF — price on request, MSA 2060 FC 24SFF — 112,711,000 UZS.
Check compatibility and build a configuration → — tell us the array model and number of drives, and we will select the shelf, drives and cables.
Quick links: how to read the name · MSA generations · expansion shelves and cables · slot and port numbering · drives and RAID · what is in the catalog
How to read the name: MSA 2060 FC 24SFF
Part of the name | What it means |
|---|---|
1060 | the entry model of the line: fewer ports and less cache, same enclosure |
2060 | the main model, two controllers in active-active mode |
2062 | the same 2060 plus two SSDs as standard — for automatically moving hot data to flash |
FC | Fibre Channel 16 or 32 Gbps — when the fabric is already built |
iSCSI | 10 or 25 GbE over a standard Ethernet network |
SAS | direct connection of two to four servers without switches |
12LFF | twelve 3.5-inch bays — capacity per rack unit |
24SFF | twenty-four 2.5-inch bays — spindle count and room for flash |
The interface is chosen first and can later be changed only together with the controllers, so a mistake here is more expensive than any other. The price also depends on the version: MSA 2060 SAS 24SFF — price on request, while the same enclosure with Fibre Channel ports costs 112,711,000 UZS.
Generations: 2040, 2050 and 2060
Generation | Years | What you need to know |
|---|---|---|
MSA 1040 / 2040 | 2013–2016 | discontinued; shelves and drives of this generation do not fit the new arrays |
MSA 1050 / 2050 / 2052 | 2017–2020 | discontinued, support limited by contract; shelves of this generation work only with their own controllers |
MSA 1060 / 2060 / 2062 | since 2020 | current line: MSA-DP+ distributed RAID, iSCSI up to 25 GbE, FC 32 Gbps |
Important for those searching by number: enclosures of different generations look the same — the same 2U for 12 or 24 drives, the same front bezel. The controllers differ, and the generation is determined by their labels. When buying second-hand, look at the controller module, not the chassis.
All models are block arrays with two controllers. They have no file services: a volume is presented to the server as a disk, and SMB or NFS is set up on the server.
Expansion shelves and cables
This is where confusion most often arises, because price lists put “array”, “shelf” and “JBOD” side by side.
- The array is the only element with controllers, cache and ports to servers. There is one management point, no matter how many shelves are attached to it.
- An expansion shelf connects to the array controllers over SAS. The array sees its drives as its own: volumes, RAID and snapshots are shared; the shelf has no management of its own. An example from the catalog is the MSA 2050 SAS 12LFF shelf for 24,800,000 UZS.
- Only a shelf of the same generation. An enclosure from MSA 2040 will not connect to 2060 controllers: the SAS expanders are of different generations, and HPE's compatibility list is closed.
The connection rules are simple and the same for the whole line:
- a shelf is connected with two SAS cables, one per controller: a break in one cable must not take the shelf offline;
- the cables run from the expansion ports of the array controllers to the ports of the shelf I/O modules, and the next shelf connects to the previous one in a cascade;
- the maximum number of shelves and drives depends on the model and firmware version — before buying a second or third shelf it is worth checking the configuration against the current QuickSpecs;
- LFF and SFF enclosures can be mixed in one system, but disk groups are built within a single drive type.
Slot and port numbering: what “slot 4” and “slot 6” are
A search question that comes up when reading logs and connection diagrams. MSA numbers three different things, and they should not be confused.
- Drive slots. Numbered left to right and top to bottom, starting from one. In a 12LFF drive cage this is three rows of four drives, in 24SFF one row of twenty-four. In the array logs a drive is identified by a pair “enclosure number and slot number”; the first enclosure is the array itself, and shelves are numbered next in connection order.
- Ports to servers. Each controller has its own ports, numbered separately; in a dual-controller system addressing is always paired — controller A and controller B.
- Expansion ports. Separate SAS connectors on the controller; this is where shelves are connected. They cannot be used as host ports for servers, and vice versa.
The practical conclusion: if “slot 4” and “slot 6” appear in documentation or a log, first figure out what is meant — a drive slot in the cage or a port. Each model has its own cabling diagram, and it should be taken from the guide for your specific generation: they differ between 2040, 2050 and 2060.
Drives and RAID
- Only drives with HPE firmware. The array will see a third-party drive but mark it as unsupported and will not add it to a disk group. This is a check in the controller firmware, not marketing.
- Drive trays differ between generations and between LFF and SFF cages. When buying drives separately, check the trays specifically — otherwise the drive will arrive and there will be nowhere to install it.
- MSA-DP+ is the current generation's distributed RAID: spare capacity is spread across all drives, so the rebuild after a failure is noticeably faster than with classic RAID 6 and is not limited by the speed of a single drive.
- Classic RAID 5 on drives of 8 TB and up is not advisable: the rebuild takes more than a day, and a second failure during that time stops being hypothetical. A breakdown of levels is in the article RAID and the server disk subsystem.
- Do not fill the array beyond 80% — on an overfilled pool both writes and rebuild speed degrade.
What is in the catalog
Model | Interface | Drive bays | Price |
|---|---|---|---|
SAS 12G | 24 × 2,5" | price on request | |
SAS 12G | 12 × 3,5" | price on request | |
FC 16/32G | 12 × 3,5" | 88,277,000 UZS | |
iSCSI 10/25G | 12 × 3,5" | 93,084,000 UZS | |
FC 16/32G | 24 × 2,5" | 112,711,000 UZS | |
iSCSI | 24 × 2,5" | 105,000,000 UZS | |
FC, two SSDs included | 24 × 2,5" | 126,800,000 UZS | |
FC, two SSDs included | 12 × 3,5" | 131,333,000 UZS | |
expansion shelf | 12 × 3,5" | 24,800,000 UZS |
Configuration breakdown and capacity calculation are on the page HPE MSA 2060 and 2062, all arrays are in the section HPE storage. How the Dell line with the same naming logic is structured is in the Dell PowerVault reference.
What to check before ordering
- Server interface — it can later be changed only together with the controllers.
- Array generation, if a shelf or drives are being added to an existing system.
- Drive cage type: LFF for capacity or SFF for spindle count and flash.
- Drive trays — they are specific to each generation and cage type.
- Cabling diagram for your model: it differs between 2040, 2050 and 2060.
- Capacity headroom: the array should not run filled beyond 80%.
We will check the compatibility of your configuration, select a shelf and drives for your existing array, or build a new one — write to us.
Sources
Other Servix collections
- Server configurations and prices
- Server for 1C: configurations and prices
- How to choose a Dell PowerEdge
- HPE ProLiant Gen11: configurations and prices
- FortiGate by number of employees
- Dell PowerVault ME5 storage systems
- HPE MSA 2060 and 2062 storage systems
- Aruba Instant On for the office
- Network adapters, transceivers and DAC
- Xeon and EPYC server processors
- Drives and RAID controllers
- Server for video surveillance
- Dell PowerVault reference guide
- RAID controller reference guide
- Server for virtualization
- File server and backup