Dell PowerVault: what ME5012, ME4084 and MD2460 mean — models, expansion shelves and drive compatibility
Updated
In brief. The name of a Dell PowerVault array encodes its entire geometry: ME5012 — twelve 3.5-inch drives, ME5024 — twenty-four 2.5-inch drives, ME5084 — eighty-four drives in pull-out drawers. ME5 is the current generation, ME4 the previous one, MD a discontinued line. Expansion shelves are named differently: ME412, ME424, ME484 — the same numbers, but without controllers. In the Servix catalog the ME5012 FC is price on request, the ME412 shelf is 93,000,000 UZS, and the MD1400 disk shelf is 33,000,000 UZS.
Check compatibility and build a configuration → — send us the array model and number of drives, and an engineer will tell you which shelves and drives will fit.
Quick links: how to read the name · MD, ME4 and ME5 generations · model table · expansion shelves · drive compatibility · what MD and ME4 owners should do
How to read the name: ME5024, MD2460, ME484
Dell uses a single scheme, and once you have worked it out, you can reconstruct the configuration from the model number without opening the datasheet.
Part of the name | What it means | Examples |
|---|---|---|
ME5 | current-generation array — with controllers, cache, RAID and ports to servers | ME5012, ME5024, ME5084 |
ME4 | previous-generation array, same enclosure geometry | ME4012, ME4024, ME4084 |
ME4xx (three digits) | expansion shelf without controllers — connects to the array over SAS | ME412, ME424, ME484 |
MD14xx | JBOD disk shelf for a server: connects directly to an HBA and has no RAID of its own | MD1400, MD1420 |
MD (the rest) | discontinued line of arrays and dense enclosures from previous years | MD2412, MD2424, MD2460 |
last two digits | number of drive bays | 12, 24, 60, 84 |
The drive form factor follows from the number of bays: 12 and 84 bays mean 3.5-inch drives (LFF, capacity), 24 bays mean 2.5-inch drives (SFF, speed and spindle count). Enclosures for 60 and 84 drives are dense; the drives stand vertically in pull-out drawers, and the height of such an enclosure is no longer 2U but 4–5U.
Hence a simple check when reading a price list: if the line says “MD2460 60LFF”, it is a dense enclosure for sixty 3.5-inch drives from the old line. If it says “ME5024 FC 24SFF”, it is a current array for twenty-four 2.5-inch drives with Fibre Channel ports.
Generations: MD, ME4 and ME5
Family | What it is | Server interfaces | Status |
|---|---|---|---|
MD3 (MD3400, MD3800, dense MD24xx) | arrays of the previous decade, separate management system | SAS 12G, iSCSI 1/10G, FC 8/16G | discontinued; supplied only made to order from remaining stock |
ME4 (ME4012, ME4024, ME4084) | first generation of the unified ME line, PowerVault Manager web interface | SAS 12G, iSCSI 10G, FC 16/32G | discontinued, support limited to the contract term |
ME5 (ME5012, ME5024, ME5084) | current generation: twice the cache, newer processors, ADAPT and snapshots included as standard | SAS 12G, iSCSI 10/25G, FC 16/32G | current, made to order |
Important for those searching by model number: ME4084 and ME5084 are the same 84-drive enclosure; the difference is in the controllers. Likewise, ME4024 and ME5024 are indistinguishable from the outside. So when buying second-hand, look not at the enclosure but at the controller labels: they determine the firmware, the support and which shelves will fit.
All three families are block arrays with two controllers in active-active mode. They have no file services (SMB, NFS): a volume is presented to the server as a disk, and file access is set up on the server. If you need file access out of the box, that is a different class of equipment.
Model table: bays, height, purpose
Model | Bays | Height | Type | In the catalog |
|---|---|---|---|---|
ME5012 | 12 × 3,5" | 2U | array, two controllers | ME5012 FC 12LFF — price on request |
ME5024 | 24 × 2,5" | 2U | array, two controllers | ME5024 SAS 24SFF — price on request |
ME5084 | 84 × 3,5" | 5U, pull-out drawers | array, two controllers | made to order |
ME412 | 12 × 3,5" | 2U | expansion shelf | ME412 SAS 12LFF — 93,000,000 UZS |
ME424 | 24 × 2,5" | 2U | expansion shelf | made to order |
ME484 | 84 × 3,5" | 5U, pull-out drawers | expansion shelf | ME484 84LFF — 175,000,000 UZS |
MD1400 | 12 × 3,5" | 2U | JBOD to a server via HBA | MD1400 12 bays — 33,000,000 UZS |
MD1420 | 24 × 2,5" | 2U | JBOD to a server via HBA | made to order |
MD2412 | 12 × 3,5" | 2U | previous-line array | MD2412 12LFF — 118,000,000 UZS |
MD2460 | 60 × 3,5" | 4U, pull-out drawers | previous-line dense enclosure | made to order |
Prices are for specific catalog items and depend on the drive configuration: an empty chassis and the same chassis with twelve 16 TB drives differ almost twofold. The full ME5 line with an interface breakdown is on the page Dell PowerVault ME5 configurations and prices.
Expansion shelves: what connects to what
This is where confusion most often arises, because price lists put the words “shelf”, “JBOD” and “array” side by side, and these are three different things.
- The ME412, ME424, ME484 expansion shelf connects over SAS to the controllers of an ME4 or ME5 array. The array sees the drives in it as its own: volumes, RAID and snapshots are shared. The shelf has no management of its own.
- The MD1400 and MD1420 JBOD connects not to an array but to the server's SAS controller. It is a way to cheaply add twelve or twenty-four drives to a server, not to expand a storage system. RAID is then built by the server's controller.
- The array is the only element with controllers, cache and ports to servers. One array has one management point, no matter how many shelves are attached to it.
Rules for connecting shelves to ME5, according to Dell documentation:
- ME5012 and ME5024 are expanded with ME412 and ME424 shelves — up to ten shelves, that is, up to 132 LFF drives or 264 SFF drives;
- ME5084 is expanded with ME484 shelves — up to three shelves, that is, up to 336 drives;
- shelves are connected with two SAS cables (one per controller) in a redundant layout: a break in one cable must not take the shelf offline;
- old MD1200 and MD1220 shelves and MD24xx enclosures cannot be connected to ME5 arrays — these are different generations of SAS expanders.
The exact maximum number of shelves also depends on the controller firmware version, so before buying a second or third shelf it is worth checking the configuration against the current compatibility list.
Drive compatibility: how Dell differs from generic enclosures
PowerVault arrays work only with drives carrying Dell firmware. This is not a marketing restriction but a check in the controller firmware: the array will see a drive from another vendor but mark it as unsupported and will not add it to a disk group. Several practical consequences follow.
- Drive trays are not interchangeable between generations. 3.5-inch drive trays from the MD line do not fit ME5, and the dense 60- and 84-drive enclosures use their own trays for pull-out drawers. When buying drives separately from the array, check the trays specifically, otherwise the drive will arrive and there will be nowhere to install it.
- A 2.5-inch drive in a 3.5-inch bay can only be installed with an adapter tray. It is not available in all configurations, and for an array it is always a compromise: the bay is taken, but density has not increased.
- Drives in one disk group must be identical. If you mix 8 and 16 TB, the group aligns to the smaller capacity, and half the capacity is lost.
- SSD and HDD are not mixed in one group. Hybrid setups are built as separate groups: SSD for hot data, HDD for cold data.
On RAID levels: on drives of 8 TB and up, only RAID 6 or ADAPT makes sense — Dell's distributed scheme, which rebuilds faster than classic RAID thanks to spare capacity spread across all drives. RAID 5 must not be used on large drives: the rebuild takes more than a day, and a second failure during that time stops being hypothetical. A detailed breakdown of levels is in the article RAID and the server disk subsystem.
What to do if you own an MD2460 or ME4084
A typical situation: a previous-generation array is working, but support is ending or capacity is running out. There are three options, and the choice depends on how old the enclosure is.
- Add drives to the existing bays. The cheapest path, if bays are free and drives of the right model can still be found. The ceiling is the number of bays in the enclosure.
- Add a shelf of the same generation. This works for ME4, which accepts ME412, ME424 and ME484. For the MD line, shelves are harder to find, and each new shelf extends the life of a platform that no longer receives firmware updates.
- Install an ME5 alongside and migrate the volumes. The right path if the enclosure is more than five years old. Migration is done at the server level — by data replication or hypervisor tools, not by “moving the drives over”: disk groups do not transfer between generations.
A separate note on drives during the transition: drives from ME4 physically fit in ME5 (same trays, same generation), but the disk group will still have to be created from scratch — the metadata is tied to the controllers. Plan the migration with a window in which the data is copied completely and the old array remains available for rollback.
What this costs in money and how it differs from buying servers with local drives is covered in the article how much a server costs in Tashkent.
We will check the compatibility of your configuration, select shelves and drives for your existing array, or build a new one — write to us. Arrays and shelves with prices are in the section Storage systems, the current line is on the page Dell PowerVault ME5.
Sources
Other Servix collections
- Server configurations and prices
- Server for 1C: configurations and prices
- How to choose a Dell PowerEdge
- HPE ProLiant Gen11: configurations and prices
- FortiGate by number of employees
- Dell PowerVault ME5 storage systems
- HPE MSA 2060 and 2062 storage systems
- Aruba Instant On for the office
- Network adapters, transceivers and DAC
- Xeon and EPYC server processors
- Drives and RAID controllers
- Server for video surveillance
- RAID controller reference guide
- HPE MSA reference guide
- Server for virtualization
- File server and backup