Server drives: HDD or SSD, SAS, SATA or NVMe — what to buy for the DL380 and R750

Servix technical team · Updated

In brief. For databases and virtual machines, choose SSDs; for files and backups, large-capacity SAS HDDs. In Tashkent, capacity on 8–⁠22 TB drives costs 294,000–⁠431,000 UZS per terabyte, and a terabyte on NVMe costs about 2,246,000 UZS (Servix catalog, November 2026). RAID 5 is not used on drives of 8 TB and up: a rebuild takes a full day. The controller is selected for the drive type — NVMe needs a tri-mode controller; a regular SAS controller will not see them.

What goes in the server bays: LFF or SFF

First, look not at the drive but at the drive cage. In HPE ProLiant and Dell PowerEdge servers, the cage is fixed when the chassis is ordered and can only be changed by replacing the backplane, so a mistake here is expensive.

  • LFF, 3.5 inches. Eight or twelve bays in 2U. This is where 8–⁠22 TB drives go. This is about terabytes: archive, file share, backup repository, video surveillance.
  • SFF, 2.5 inches. Eight, sixteen or twenty-four bays in 2U, eight or ten in 1U. This is where SAS 10k, SSD and NVMe go. This is about operations per second: virtualization, 1C, databases.

A drive is installed in a drive tray. HPE and Dell drive trays differ, and they also differ between generations, so a drive without a tray simply will not lock into the bay. When ordering, this is a separate line item and it is easy to forget.

HDD or SSD, SAS, SATA or NVMe: what limits what

Type

Strengths

Use case

Catalog example

Price

Per terabyte

HDD SAS 7,2k

price per terabyte, dual-port connection

files, backup, video

WD Ultrastar DC HC320 8 TB SAS

3,234,705 UZS

404,000 UZS

HDD SAS 7.2k, large

maximum capacity per bay

archive and backup repository

WD Ultrastar DC HC570 22 TB SAS

8,625,882 UZS

392,000 UZS

HDD SATA

cheaper than SAS at the same capacity

single server, non-critical data

WD Ultrastar DC HC570 22 TB SATA

6,469,411 UZS

294,000 UZS

SSD SATA

affordable flash capacity

warm data, file cache

Intel D3-S4520 7.68 TB SATA

10,782,352 UZS

1,404,000 UZS

NVMe U.3

latency and operations per second

DBMS, 1C, virtualization

Micron 7400 Pro 1.92 TB U.3

4,312,941 UZS

2,246,000 UZS

Three things distinguish a server drive from a regular one. The first: SAS is dual-port — it is visible to both controllers, so it is used in fault-tolerant configurations and in storage systems, whereas SATA is single-port. The second: CMR versus SMR recording — SMR drives are cheaper, but their performance collapses under random writes, and they are not used in RAID. The third: server SSDs have power loss protection and a rated write endurance, while consumer ones do not.

A separate note on NAS drives such as the WD Red Plus 10 TB (price on request) and the WD Red Plus 4 TB for 1,868,941 UZS. They are designed for home and office storage: 5400–⁠7200 rpm and a workload of about 180 TB written per year. For a server under constant load, choose the Ultrastar line — it is designed for 24/7 operation and for many times higher annual writes.

How many drives and which RAID for your task

  • 1C and databases. Four or more SSDs in RAID 10. Transaction logs generate random writes in small blocks; what matters here is latency, not total terabytes.
  • Virtualization. Six to eight SSDs or NVMe drives in RAID 10, a separate boot volume for the hypervisor. RAID 5 under a mixed workload carries a write penalty large enough to spoil virtual machine responsiveness.
  • File server and archive. RAID 6 of four or more large drives. Double parity is not overcaution: a 16–⁠22 TB drive takes more than a day to rebuild, and a second failure within that window is quite likely.
  • Backups. RAID 6, maximum-capacity drives, a hot spare is a must. The workload is sequential; the speed of an individual drive is not the main thing here.

A detailed comparison of the levels is in the guides RAID and the server disk subsystem and RAID 5, 6 or 10 for storage systems. If several servers need the data at once, drives in a server no longer solve the task — see the breakdown of SAN, NAS and all-flash.

Which controller to choose

The controller determines which drives the server will see at all and how fast it will write. Three boundaries matter when choosing.

  • Cache and battery. Models without cache (E208 from HPE, H345 from Dell) are suitable for RAID 1 and 10 or for HBA mode. RAID 5 and 6 need cache with battery protection; otherwise write performance collapses, and on power loss the data in the cache is lost.
  • Tri-mode. Only controllers with tri-mode support work with NVMe U.2 and U.3 — these are the MR416i from HPE and the H755 from Dell. A classic SAS controller simply will not see an NVMe drive.
  • Internal or external. The suffix i means ports facing inside the chassis, e means ports facing outside, for connecting a disk shelf. The P408e-p and E208e-p are external ones.

Controller

Cache and battery

Drives

Price

Dell PERC H345

no

SAS, SATA, RAID 1 and 10

4,312,941 UZS

Dell PERC H730 with battery

yes

SAS, SATA, all RAID levels

5,750,588 UZS

Dell PERC H750 with battery

yes

SAS 12G, SATA

7,188,235 UZS

Dell PERC H755 with battery

yes

SAS, SATA and NVMe (tri-mode)

8,625,882 UZS

HPE Smart Array E208i-a

no

SAS, SATA, RAID 1 and 10

5,750,588 UZS

HPE Smart Array P408i-a

yes

SAS 12G, SATA, all levels

7,188,235 UZS

HPE Smart Array P408e-p

yes

external ports for a shelf

7,188,235 UZS

HPE MegaRAID MR416i-p, 4 GB cache

yes

NVMe and SAS 12G (tri-mode)

9,344,705 UZS

If the server has more bays than the controller has ports, an expander is installed between them — for example, the HPE 12G SAS Expander for 7,188,235 UZS. This is cheaper than a second controller, but the bandwidth is shared among all the drives behind it.

Where to put the hypervisor: the boot volume

Giving two cage bays to the system is wasteful, so separate modules with a pair of M.2 drives in a mirror are used for booting: Dell BOSS-S2 with two 480 GB M.2 SATA drives (for 15th generation PowerEdge) for 7,907,058 UZS and HPE NS204i-p with two 480 GB NVMe drives for 10,063,529 UZS. The mirror is built by the module itself, the hypervisor sees one disk, and all cage bays remain for data. For ESXi, Proxmox and Hyper-V this is the standard scheme.

Why you should buy drives in vendor drive trays

A server works with a third-party drive too, but with caveats. Vendor firmware adds health monitoring in iLO and iDRAC: failure prediction, error counters, automatic support case creation. With a third-party drive, this data is either incomplete or missing, and when you contact support the configuration is considered modified. Plus the mechanics: each generation has its own drive trays, and without them a drive does not lock into the bay and does not connect to the backplane.

Practical conclusion: for a production server, buy drives in trays for your generation and check compatibility before ordering. We do this free of charge — send us the server model and serial number.

Three ready-made sets with prices

The amounts are for the drive part: the server itself is calculated separately; ready-made configurations are on the pages HPE ProLiant Gen11 and Dell PowerEdge. Sizing for 1C is in the article server for 1C by number of users.

Warranty and lead times in Tashkent

All items in the drives and RAID controllers catalog come with a warranty of 12 months, serviced by Servix. Supply is made to order — 2–⁠3 weeks, and the price is fixed in the invoice. We work by bank transfer with VAT, prepare specifications for tenders, and deliver throughout Uzbekistan. Selection of drives and a controller for your server model is free: write to us or call +998 92 182 11 44. Other components are in the Server componentssection.

Questions and answers

How much does a server drive cost in Tashkent?

An 8 TB SAS drive costs 3,234,705 UZS, 16 TB — 5,031,764 UZS, 22 TB — 8,625,882 UZS. A 1.92 TB NVMe U.3 drive costs 4,312,941 UZS, a 7.68 TB SATA SSD — 10,782,352 UZS (Servix catalog, November 2026).

Can a regular desktop drive be installed in a server?

Technically it will be detected, but it lacks dual-port SAS, endurance for 24/7 load and vendor firmware, and monitoring in iLO and iDRAC will be incomplete. For a production server, choose a server line in trays for your generation.

Which RAID to choose for 1C and virtualization?

RAID 10 of four or more SSDs. RAID 5 carries a write penalty, and on drives of 8 TB and up it is also dangerous because of the long rebuild — for such capacities RAID 6 is used.

Do you need a controller with cache and battery?

For RAID 5 and 6 — definitely: without cache, write performance collapses, and without a battery, the data in the cache is lost on power loss. For RAID 1 and 10 or HBA mode, a model without cache such as the PERC H345 or Smart Array E208i-a is enough.

Related reading