Skip to content

Dear customers! Please send orders and inquiries to [email protected] or to Telegram @servix_uz instead of calling by phone: due to the high workload, the operator cannot answer all incoming calls.

Servix

SFF or LFF: which drive bays to choose in a server

Servix technical team · Updated

In brief. SFF means bays for 2.5″ drives, LFF for 3.5″, and the number before the letters is how many such bays are in the front cage. LFF is chosen for capacity: 3.5″ bays take 16–⁠22 TB HDDs at 294,000–⁠392,000 UZS per terabyte (Servix catalog, November 2026); this is for video archives, backup and file storage. SFF is chosen for speed: SSD and NVMe for virtualization, databases and 1C, up to 24 bays in front in 2U. NVMe goes only into SFF or E3.S with an NVMe backplane, and the cage is chosen when ordering: on the HPE DL380, an 8LFF chassis cannot be converted to 12LFF on site.

The names of servers in the catalog constantly include 4LFF, 8SFF, 12LFF and 24SFF. Behind these letters is a decision that is hard to reverse later: which drives will fit in the server, how many there will be and whether NVMe can be installed. This article is for those who are choosing a server and want to understand the drive cage before selecting drives. The drives themselves — HDD and SSD, SAS, SATA and NVMe — are covered in the article “Server drives: HDD or SSD, SAS, SATA or NVMe”; here we focus on the bays.

What 8SFF, 12LFF and 24SFF mean

SFF (Small Form Factor) is a bay for a 2.5-inch drive, LFF (Large Form Factor) is a bay for a 3.5-inch drive. The number in front is the number of bays in the front cage. A cage is a frame with bays plus a backplane: the board behind them that the drive connector plugs into and from which cables run to the controller or processor. The backplane determines which interfaces will work: only SAS and SATA, or NVMe as well.

The product name describes only the front panel. Two-unit servers have middle and rear bays, so the actual number of drives can be larger:

  • HPE ProLiant DL380 Gen11. 8, 16 or 24 SFF in front and up to 6 SFF in the rear, up to 30 in total. Or 8 or 12 LFF in front; 4 LFF in the rear can be added to 12LFF, 16 in total.
  • HPE ProLiant DL380 Gen10. Up to 30 SFF (24 in front and 6 in the rear) or up to 19 LFF and 2 SFF: 12 LFF in front, 4 LFF in the middle cage, 3 LFF and 2 SFF in the rear.
  • Dell PowerEdge R760. In front, 8, 16 or 24 × 2.5″, 12 × 3.5″ or 16 × E3.S; in the rear, 2 or 4 × 2.5″ or 4 × E3.S.
  • One-unit servers. Usually 4LFF or 8–⁠10SFF: the HPE DL360 Gen10 is in the catalog in 4LFF and 8SFF versions, Dell R450 in 4LFF and 8SFF, R650 in 8SFF and 10SFF, R660 in 10SFF.

Which drives fit in SFF, LFF and E3.S

2.5″ bay (SFF)

These bays take SAS and SATA SSDs, U.2 and U.3 NVMe drives (only if the backplane supports NVMe) and mechanical SAS drives at 10,000 and 15,000 rpm. Mechanical drives in 2.5″ hit a ceiling of 2.4 TB: this is the highest-capacity SFF drive in the HPE lists for the DL380 Gen11 and the Dell lists for the R760. 2.5″ SATA HDDs from HPE go up to 2 TB. That is why an SFF cage is primarily a cage for flash.

3.5″ bay (LFF)

These bays take 7200 rpm SAS and SATA HDDs. HPE and Dell documentation for the DL380 and R760 lists drives up to 18–⁠20 TB, and the Servix catalog has 22 TB WD Ultrastar drives — we check the compatibility of a specific model with your server before ordering. NVMe does not work in an LFF bay: the front 3.5″ backplanes on the HPE DL380 and Dell R760 are SAS/SATA only. An SSD can be installed in LFF, but through an adapter; more on that below.

EDSFF E3.S in new generations

E3.S is a new form factor designed for NVMe only. It is more compact: up to 36–⁠40 such drives fit in 2U versus 24 2.5″ drives in front. On the Dell R760, it is the path to NVMe PCIe Gen5: in the supported drives table from the Technical Guide, 2.5″ NVMe drives are listed as Gen4 and E3.S as Gen5. The Dell R760 takes up to 16 E3.S in front, the HPE DL380 Gen12 up to 36, the Dell R770 up to 40. According to the Technical Guide (June 2026), the R770 has no 3.5″ cage at all: only 2.5″ and E3.S. HPE kept LFF in the DL380 Gen12: 12 in front, 4 in the middle cage and up to 4 in the rear.

Capacity versus speed: what a bay gives you

A mechanical drive is limited by its heads. The Seagate Exos X18 at 7200 rpm delivers, according to the manufacturer's specification, 170 random read operations per second (4 KB block, queue depth 16) and up to 270 MB/s in sequential read. The SATA SSD D3-S4520 (Intel, now Solidigm) delivers up to 92,000 random read operations according to the manufacturer's documentation. The difference is roughly 500 times per drive. Twelve HDDs together deliver on the order of two thousand random operations — less than a single SATA SSD. NVMe is also faster in its interface: PCIe 4.0 x4 instead of SATA 6 Gbps.

With capacity, it is the opposite. One LFF bay holds 16–⁠22 TB of mechanical storage, an SFF bay holds 2.4 TB of mechanical storage or 7.68 TB of SATA flash. We calculate the cost of filling a cage using the drive prices in the catalog as of November 2026:

Cage and drives

Raw capacity

Drives, total

Per terabyte

12LFF, 12 × WD Ultrastar HC570 22 TB SATA

264 TB

77,632,932 UZS

about 294,000 UZS

12LFF, 12 × WD Ultrastar HC550 16 TB SAS

192 TB

60,381,168 UZS

about 314,000 UZS

12LFF, 12 × WD Ultrastar HC570 22 TB SAS

264 TB

103,510,584 UZS

about 392,000 UZS

24SFF, 24 × Intel D3-S4520 7.68 TB SATA SSD

184.32 TB

258,776,448 UZS

about 1,404,000 UZS

8SFF, 8 × Micron 7400 Pro 1.92 TB NVMe U.3

15.36 TB

34,503,528 UZS

about 2,246,000 UZS

A terabyte on SATA flash costs 3.6–⁠4.8 times more than on mechanical drives, and on NVMe 5.7–⁠7.6 times more. See the price per terabyte for all drives in the catalog and ready-made sets with a controller in the selection drives and RAID controllers for servers.

When to choose LFF

When you need terabytes and the workload is sequential or infrequent.

  • Video surveillance. Dozens of cameras record continuous streams, and the archive is kept for weeks. Here you calculate capacity, not operations per second — archive sizing and ready-made servers are in the selection server for video surveillance.
  • Backup repository. Writes go in large blocks at night, and restores are rare. Maximum-capacity drives save bays.
  • File archive and cold data. Documents, scans and project archives that are rarely accessed.

Which RAID to build on 16–⁠22 TB drives and why RAID 5 is not used on them is covered in the article “RAID and the server disk subsystem”.

An LFF chassis has limitations that are described in the documentation. According to Dell's thermal restrictions table, the R760 chassis with 12 × 3.5″ is rated for processors up to 250 W TDP (with 2.5″ drives — up to 350 W), the tables list no GPU configurations for it, and its fan speed is limited to 70% — Dell explains this by the profile of mechanical drives. On the HPE DL380 Gen10, Gen11 and Gen12, an 8LFF chassis cannot be converted to 12LFF on site. If capacity may grow, choose 12LFF from the start.

When to choose SFF

When latency and random access matter: virtual machines, databases, 1C, mail, terminal servers. A dozen virtual machines on one array is a stream of small random operations, and mechanical drives fall behind here even with a controller cache. How to size a server by the number of machines and licenses — in the selection server for virtualization.

SFF is also convenient because it can grow. The HPE DL380 Gen10 and Gen11 in the 8SFF version expand to 16 and 24 bays with additional 8-drive cages; with three cages, HPE requires a high-performance fan kit. SFF also works for file storage if the budget allows: 24 SSDs of 7.68 TB give 184 TB of raw capacity but cost 3.3 times more than twelve 22 TB SATA HDDs, which also have 80 TB more capacity.

Mixed and universal cages

You do not have to choose just one. HPE and Dell offer combinations where one server holds both high-capacity HDDs and fast SSDs or NVMe drives.

  • HPE DL380 Gen10. Premium 8 SFF cage: 6 SAS/SATA bays and 2 NVMe. In an LFF chassis, a rear cage for 3 LFF (in the catalog: HPE DL380 Gen10 3LFF Rear SAS/SATA Kit for 4,312,941 UZS), which takes the place of the second and third risers.
  • HPE DL380 Gen11. To 8LFF, you can add 2 SFF in front and 2 SFF or up to 4 LFF in the rear. U.3 tri-mode cages accept SAS, SATA or NVMe in the same bay — when connected to a tri-mode controller.
  • Dell R760. 12 × 3.5″ plus 2 or 4 × 2.5″ in the rear (SAS/SATA or NVMe Direct) or 4 × E3.S; 24 × 2.5″, of which 8 are universal; 16 × 2.5″ SAS/SATA plus 8 × 2.5″ NVMe.

Dell's universal backplane accepts SAS, SATA and NVMe in a bay, but they work differently: SAS and SATA go to the PERC with hardware RAID, while NVMe goes directly to the processor, without hardware RAID. A typical mixed layout is a data array on HDDs in the front LFF cage and a pair of SSDs or NVMe drives in the rear for the system, a database or cache.

NVMe: what you need besides the drives themselves

An NVMe drive simply will not work in a regular SAS/SATA cage. Check four things.

  1. A backplane with NVMe. On HPE Gen11, these are 8SFF U.3 x1 (tri-mode) or U.3 x4 (Premium) cages; the number is the PCIe lane count per bay. On the Dell R760, these are NVMe Direct, NVMe RAID or Universal configurations.
  2. What to connect through. Directly to the processor — in an x4 cage the drive gets all four lanes, but there is no hardware RAID, and the array is built by the OS or hypervisor. HPE states plainly: an x4 cage with direct connection accepts only NVMe, and an x1 cage with direct connection accepts only SATA; NVMe in it works through a tri-mode controller (MR216i or MR416i). Direct-attach NVMe packages for the DL380 Gen11 require a second processor, a cable kit and high-performance fans. Dell has a different scheme: the R760 Technical Guide states that PowerEdge does not support tri-mode, that is, mixing SAS, SATA and NVMe behind one controller. NVMe with hardware RAID at Dell is a separate NVMe RAID configuration with its own PERC.
  3. Cables and risers. For NVMe on the DL380 Gen10, HPE requires a separate SlimSAS riser and high-performance fans. The parts are sold separately in the catalog: the HPE DL380 Gen10 Plus 8SFF Tri-Mode U.3 cage — 7,188,235 UZS, the HPE DL380 Gen10 Plus riser for 4 NVMe — 7,188,235 UZS, the 2SFF NVMe riser for the Dell R750 — 3,594,117 UZS. How to choose cables for a “backplane plus controller” combination is described in the reference guide Dell PERC and HPE Smart Array RAID controllers.
  4. U.2 or U.3. U.3 is an evolution of U.2 with support for tri-mode controllers. According to Micron, U.3 drives are compatible with U.2 backplanes; backward compatibility is not guaranteed and is checked against the vendor's list. HPE supplies NVMe drives for the DL380 Gen10 in the U.2 version, and for Gen11 in U.3.

Can a 2.5″ drive be installed in a 3.5″ bay

Yes, through an adapter. HPE sells SSDs for LFF cages already in a 3.5″ adapter: in the DL380 Gen10 QuickSpecs they are marked LFF SCC (for example, HPE 960GB SATA 6G Mixed Use LFF SCC), in the DL380 Gen11 QuickSpecs — LFF LPC. Dell, in the service manuals for the 14th generation (R740, R540), describes installing a 2.5″ drive into an adapter and the adapter into a 3.5″ drive tray. The R760 drive list for 3.5″ bays includes only 7200 rpm HDDs.

What an adapter gives you: an SSD in an LFF server, for example for the system or a small fast volume. What it does not give you: NVMe (the backplane is still SAS/SATA) and density — 12LFF fits 12 SSDs, while a 24SFF of the same size fits 24. The other way around, a 3.5″ drive cannot be installed in a 2.5″ bay. 3.5″ drive trays are sold separately: for the HPE DL380 — 431,294 UZS, for Dell 15th generation — 287,529 UZS.

Configuration examples from the catalog

The servers below are sold without drives. For the DL380 Gen11, R760 and R740, the internals within a group are the same; for the pair of DL380 Gen10, they differ. Prices from the product pages as of November 2026, including 12% VAT.

Server and cage

Processors, memory, controller

Condition

Price

HPE DL380 Gen10 8SFF

2 × Xeon Silver 4210, 64 GB, P408i-a

refurbished

price on request

HPE DL380 Gen10 12LFF

2 × Xeon Silver 4210, 32 GB, P816i-a

refurbished

36,037,000 UZS

HPE DL380 Gen11 8SFF

1 × Xeon Bronze 3408U, 32 GB DDR5, MR216i-p

new

price on request

HPE DL380 Gen11 8LFF

same

new

price on request

HPE DL380 Gen11 24SFF

same

new

price on request

Dell R760 8SFF

2 × Xeon Silver 4410Y, 32 GB DDR5, PERC H755

new

price on request

Dell R760 12LFF

same

new

price on request

Dell R740 8LFF

2 × Xeon Bronze 3204, 32 GB, H730p

refurbished

25,433,000 UZS

Dell R740xd 24SFF

same

refurbished

26,364,000 UZS

What the table shows. For the Dell R740 and R740xd, the difference is less than a million UZS, but the second one has three times as many bays. Prices for the HPE DL380 Gen11 and Dell R760 are on request: the quote will show the difference between their cages. Therefore, compare not the cage type in general but specific product pages, and budget for drives: eight 1.92 TB NVMe drives are another 34.5 million UZS, twelve 16 TB HDDs are 60.4 million UZS.

Frequently asked questions

What do 8SFF and 12LFF mean in a server name?

8SFF means eight front bays for 2.5″ drives, 12LFF means twelve for 3.5″ drives. Middle and rear bays are usually not included in the name.

Can NVMe be installed in an LFF bay?

No. The front 3.5″ backplanes on the HPE DL380 and Dell R760 are designed for SAS and SATA. In an LFF server, NVMe is installed in rear or additional 2.5″ or E3.S bays, if the platform offers them.

Can 8LFF be converted to 12LFF, or LFF to SFF, later?

According to the HPE QuickSpecs, a DL380 8LFF chassis cannot be converted to 12LFF on site, while 8SFF expands to 16 and 24 bays with additional cages. At HPE, LFF and SFF are different chassis with different SKUs, so the cage type is chosen when ordering.

What is more cost-effective for a 100 TB archive?

LFF. Eight 16 TB HDDs in RAID 6 give 96 TB of usable capacity for 40,254,112 UZS. A similar capacity on SFF is sixteen 7.68 TB SSDs (107.5 TB in RAID 6) for 172,517,632 UZS, 4.3 times more expensive.

What are tri-mode and a universal backplane?

These are bays into which you can insert SAS, SATA or NVMe. At HPE, such a bay works through a tri-mode controller. At Dell, a universal bay passes SAS and SATA to the PERC controller and connects NVMe directly to the processor.

Is E3.S needed?

If you need a lot of NVMe Gen5 in one chassis — yes: in the Dell R760 drive list, Gen5 is available only in the E3.S format. For mainstream virtualization and 1C, U.2 or U.3 in an SFF cage is usually enough.

Send to [email protected] your task (virtualization, 1C, a database, a video archive or backup), the number of users or cameras, the required capacity and your budget — we will select the cage, drives, controller and drive trays for a specific model and send a quote. Prices include 12% VAT, warranty 12 months on new and refurbished equipment, serviced by Servix. Delivery within Tashkent is free, made-to-order items arrive in 2–⁠3 weeks, and the price is fixed in the invoice.

See also: SAN, NAS or all-flash: how to choose a storage system for a company, Server for 1C: configurations for 5–⁠100 users, Storage system or NAS: what to choose for an office and a company, HPE ProLiant DL380 Gen10 or Gen11: which to choose — comparison of generations and prices.