How to choose an SFP module for a Cisco, HPE Aruba, Huawei or Juniper switch
Servix technical team · Updated
In brief. Start with the part number of the original module — from the label, from the switch output or from the project specification: it immediately sets the standard (SX, LR, SR4 and so on), the transmission distance and the equipment family. Then check the fiber type and link length, make sure that the standard and wavelength are the same at both ends (for single-fiber BiDi — a U and D pair), and order modules with a code for each device. Fibreon compatible equivalents for Cisco, HPE Aruba, Huawei and Juniper part numbers are collected in tables on fibreon.uz; flashing for your equipment is free.
This is a step-by-step selection procedure for an administrator who is adding modules to a working network or putting together a specification for a new project. A compatible module differs from the original in the code in its memory, by which the switch recognizes its “own” module, so selection always starts from the specific equipment. At the end there is a table of common original part numbers with Fibreon compatible equivalents. The basics of connectors and speeds are in the article “Network adapters and transceivers”.
Step 1. Find the part number of the original
The part number is printed on the module label. At Cisco, it is a PID such as SFP-10G-SR; at Huawei, a module is also designated by an eight-digit BOM code. If the module is already in a port, the data can be seen from the command line:
- Juniper — show chassis hardware: modules appear as Xcvr lines with an internal part number such as 740-021308, and in the Hardware Compatibility Tool this number is mapped to the ordering number — for the example above, it is EX-SFP-10GE-SR;
- Huawei — display transceiver interface with the port name and the option verbose: general and manufacturing data of the module, including the manufacturer's part number;
- Cisco — show interfaces transceiver detail: module diagnostics, while the PID is on the label;
- a Linux server — ethtool -m: the contents of the module memory, including the manufacturer and part number.
If there are no modules yet, the part numbers are taken from the manufacturer's compatibility lists: Cisco — Transceiver Module Group Compatibility Matrix, HPE Aruba — AOS-S and AOS-CX Transceiver Guide, Juniper — Hardware Compatibility Tool. For servers, look at the list of modules in the network adapter specification, not in the server specification.
How to read part numbers
- Cisco. GLC-… are gigabit modules, SFP-10G-… and SFP-25G-… are 10G and 25G, QSFP-40G-… and QSFP-100G-… are 40G and 100G, MA-… is the Meraki line. The suffix indicates the class: -S — S-class modules, commercial range 0…70 °C, without FCoE; -X — extended range −5…85 °C and multi-rate with OTU2 support; -I — industrial range −40…85 °C.
- HPE. One standard — several part numbers for different equipment families. A 10GBASE-SR module is J9150D for Aruba switches, R9D18A for the Instant On line, 455883-B21 for ProLiant and BladeSystem servers, as well as JD092B and JQ431A. In the AOS-CX documentation, HPE classifies modules made for Comware switches and for HPE servers as unsupported, so what matters is which equipment the module will go into, not just “HPE”.
- Huawei. A module has a name (OMXD30000, SFP-10G-SR, QSFP28-100G-SR4) and an eight-digit BOM code (02318169, 02311GBW). By the BOM code, the module can be found unambiguously in the compatible equivalents table.
- Juniper. The prefix indicates the family: EX-SFP-…, QFX-SFP-…, SRX-SFP-…, as well as the general JNP-… and SFPP-…; in the device output — the internal number 740-….
- Dell and MikroTik. Dell optics come under ordering codes 407-…, DAC cables under 470-…, plus names such as SFP-10G-SR. MikroTik uses codes such as S+85DLC03D or XS+85LC01D.
Step 2. Standard, transmission distance and fiber
The part number determines the standard, and the standard determines the wavelength, fiber type and transmission distance. Reference points per IEEE 802.3 and manufacturer specifications:
Standard | Form factor | Wavelength | Fiber and connector | Transmission distance |
|---|---|---|---|---|
1000BASE-SX | SFP 1G | 850 nm | multimode, LC duplex | 550 m over OM2 |
1000BASE-LX | SFP 1G | 1310 nm | single-mode, LC duplex | 10 km |
10GBASE-SR | SFP+ 10G | 850 nm | multimode, LC duplex | 300 m over OM3 |
10GBASE-LR | SFP+ 10G | 1310 nm | single-mode, LC duplex | 10 km |
10GBASE-ER | SFP+ 10G | 1550 nm | single-mode, LC duplex | 40 km |
25GBASE-SR | SFP28 25G | 850 nm | multimode, LC duplex | 70 m over OM3, 100 m over OM4 |
25GBASE-LR | SFP28 25G | 1310 nm | single-mode, LC duplex | 10 km |
100GBASE-SR4 | QSFP28 100G | 850 nm | multimode, MPO-12 | 70 m over OM3, 100 m over OM4 |
100GBASE-LR4 | QSFP28 100G | four wavelengths 1295–1310 nm | single-mode, LC duplex | 10 km |
What else to check on the link:
- Fiber type. A multimode module will not connect with a single-mode one. Single-mode cable is usually yellow, OM3 and OM4 are aqua or violet, OM2 is orange.
- Attenuation, not kilometers. The transmission distance in the table is given for standard fiber; on a real link it is eaten up by splices, connectors and patch panels. Fibreon product pages state the module's link budget — for example, 13 dB for the FBN-S1-LX20 — and the calculated attenuation of the path is compared against it.
- Short link and a powerful module. A module rated for 40 km or more can overload the receiver on a link of a couple of kilometers: for 10GBASE-ER on links shorter than 20 km, Cisco requires a 5 dB attenuator.
- Gigabit over multimode at 1310 nm. Cisco allows 1000BASE-LX to run over multimode fiber up to 550 m, but only through a special mode conditioning patch cord.
Step 3. A single fiber: BiDi pairs
When only one fiber strand is free, single-fiber BiDi (WDM) modules are used. They transmit and receive on different wavelengths and work only in pairs: one end has a U module, the other a D module. Both are ordered at once. Two pitfalls:
- Wavelength pairs differ between vendors. The gigabit Cisco GLC-BX-U and GLC-BX-D work on the 1310/1490 nm pair. Juniper has both pairs, and this is visible from the part number: EX-SFP-GE10KT13R14 transmits at 1310 nm and receives at 1490 nm, EX-SFP-GE10KT13R15 at 1310 and 1550 nm. MikroTik's gigabit BiDi modules for 20 km use the 1310/1550 nm pair. Modules from different pairs will not connect to each other. The catalog has both options: FBN-S1-BX20-34-SC and FBN-S1-BX20-43-SC at 1310/1490 nm are compatible equivalents of Cisco, HPE and Huawei; FBN-S1-BX20-U and FBN-S1-BX20-D at 1310/1550 nm are compatible equivalents of Juniper and MikroTik.
- Connector. The Cisco GLC-BX-U has an LC connector, while its compatible equivalent FBN-S1-BX20-34-SC has SC. This is noted in the compatible equivalents table; an SC patch cord is needed.
At 10G, BiDi pairs are built on 1270/1330 nm: Fibreon modules for 10, 20 and 40 km are in the SFP+ 10G section.
Step 4. Flashing for the equipment
The compatibility code is written for specific equipment, so the order needs:
- the manufacturer and model of the switch, router or network adapter at each end of the link;
- for a server — the network adapter model: the module is checked by the adapter it is inserted into, not by the server;
- if the ends have equipment from different manufacturers — modules of the same standard and wavelength, but with different codes.
Flashing Fibreon modules for your equipment is free. After installation, check that the module is recognized without warnings and that the receiver power in DDM diagnostics is within the module's sensitivity. All Fibreon optical modules have DDM.
Table: common original part numbers and Fibreon compatible equivalents
A selection from the compatibility tables on the brand's website. The link in the last column leads to the module's product page in the Servix catalog, where the price and availability are shown.
Original part number | Standard | Transmission distance | Fibreon model |
|---|---|---|---|
Cisco GLC-SX-MMD | 1000BASE-SX | 550 m | |
Cisco GLC-LH-SMD | 1000BASE-LX | 10 km | FBN-S1-LX20, up to 20 km |
Cisco GLC-TE | 1000BASE-T | 100 m | |
Cisco SFP-10G-SR, SFP-10G-SR-S | 10GBASE-SR | 300 m | |
Cisco SFP-10G-LR | 10GBASE-LR | 10 km | |
Cisco SFP-25G-SR-S | 25GBASE-SR | 100 m | |
Cisco QSFP-100G-SR4-S | 100GBASE-SR4 | 100 m | |
HPE J4858D | 1000BASE-SX | 550 m | |
HPE J9150D | 10GBASE-SR | 300 m | |
HPE J9151E | 10GBASE-LR | 10 km | |
HPE JL484A | 25GBASE-SR | 100 m | |
HPE J9281D | SFP+ 10G DAC cable | 1 m | |
Huawei OMXD30000 (BOM 02318169) | 10GBASE-SR | 300 m | |
Huawei OSX010000 (BOM 02318170) | 10GBASE-LR | 10 km | |
Huawei SFP-25G-SR (BOM 02311KNR) | 25GBASE-SR | 100 m | |
Huawei QSFP28-100G-LR4 (BOM 02311KNU) | 100GBASE-LR4 | 10 km | |
Juniper EX-SFP-1GE-LX | 1000BASE-LX | 10 km | FBN-S1-LX20, up to 20 km |
Juniper EX-SFP-10GE-SR | 10GBASE-SR | 300 m | |
Juniper JNP-SFP-25G-SR | 25GBASE-SR | 100 m | |
Juniper JNP-QSFP-100G-LR4 | 100GBASE-LR4 | 10 km |
Full tables with legacy and rare part numbers are on the Fibreon website: Cisco, HPE, Huawei, Juniper, Dell and MikroTik. They also have a “Difference” column: for example, the Cisco GLC-ZX-SMD has a transmission distance of about 70 km with a 21 dB budget, the FBN-S1-ZX — 80 km, and the original 40G and 100G LR4 Lite modules are rated for 2 km, while the compatible equivalent is rated for 10 km.
What to send for selection
- Equipment models at both ends of each link.
- Part numbers of the modules you are replacing or adding — from the label or from the output of the commands above.
- Fiber type (single-mode or OM2, OM3, OM4) and link length, and if the link is long, its attenuation.
- Number of free fiber strands: two or one — this determines whether BiDi modules are needed.
- Conditions: a regular server room or an unheated outdoor cabinet.
- Quantity of modules for each item.
Frequently asked questions
Where can I find the part number if the module is already installed in the switch?
On the module label, and for Juniper and Huawei also in the output of show chassis hardware and display transceiver … verbose. On a Linux server, use ethtool -m.
The required part number is not in the table. What should I do?
Send us the equipment model and the task — speed, distance, fiber type. We will select a module by standard and flash it for your equipment.
Will a module with a Cisco code work in a Huawei switch?
No: Huawei will see it as a third-party module. The code is written for specific equipment when ordering, so specify the model the module will go into.
The ends of the link have switches from different manufacturers. Which modules should I choose?
Modules of the same standard and wavelength, but with different codes: each for its own device. For example, 10GBASE-SR with a Cisco code at one end and with a Huawei code at the other.
The compatible equivalent has a longer transmission distance than the original. Is that normal?
Yes, the differences are listed in the “Difference” column of the compatible equivalents tables. On a short link, check whether an attenuator is needed — this applies to modules rated for 40 km or more.
I need a module for an outdoor cabinet. Will Fibreon work?
Fibreon modules are rated for 0…70 °C. If the cabinet sees frost or extreme heat, you need an industrial-range module — at Cisco, that is the -I suffix, −40…85 °C.
Send to [email protected] or on Telegram @servix_uz the list from the “What to send for selection” section — we will select Fibreon compatible equivalents by part number and send a quote. The modules are in stock in Tashkent, flashing for your equipment is free, warranty 1 year with replacement through Servix.
See also: network adapters and transceivers: SFP+, SFP28, QSFP28 — what connects to what, choosing a 10/25/40G network adapter, transceivers and DAC, compatible SFP modules: how they work and when to buy an original, SFP28, QSFP28 and DAC for 25G and 100G in the data center.
Related reading
Compatible SFP modules: how they work, how they differ from original ones and how to choose
How a compatible SFP differs from an original: MSA, the code in EEPROM, DDM, module checks in Cisco, HPE Aruba, Huawei and Juniper, warranty and when an original is needed.
SFP28, QSFP28 and DAC for the server room and data center: what to choose for 25G and 100G
When to use DAC and when optics at 25G and 100G: cable length and FEC, SR or LR, MPO or LC, breakout cables. Fibreon modules and DAC cables are in stock in Tashkent.
Network adapters and transceivers: SFP+, SFP28, QSFP28 — what connects to what
SFP+ 10G, SFP28 25G, QSFP+ 40G and QSFP28 100G: which module goes into which port, DAC or optics, the MPO connector, PCIe lanes and module prices in Tashkent.
Office switch with 24 and 48 ports: Cisco 9200 and C1000, Aruba 1930, FortiSwitch
How many ports and how much PoE an office with 20, 50 and 100 workstations needs; comparison of Cisco Catalyst 9200 and C1000, HPE Aruba Instant On 1930 and FortiSwitch with prices in UZS. Tashkent.