Skip to content

Dear customers! Please send orders and inquiries to [email protected] or to Telegram @servix_uz instead of calling by phone: due to the high workload, the operator cannot answer all incoming calls.

Servix

RAID calculator: usable array capacity

Choose a RAID level and the number and capacity of drives — the calculator shows how much space is left for data, how many drives can fail, write speed and rebuild time.

Array

RAID level

RAID 5: Parity, −1 drive

  • A drive the controller automatically puts in place of a failed one. It is not included in the capacity.

How the calculator works

  1. Usable capacity: RAID 0 — all drives, RAID 1 — one drive of two, RAID 5 — minus one drive for parity, RAID 6 — minus two, RAID 10 — half of the drives, RAID 50 and 60 — minus one or two drives in each group.
  2. Capacity is calculated in TB, as drive manufacturers do (1 TB = 10¹² bytes). Windows and Linux use TiB (2⁴⁰ bytes) and show about 9% less — the calculator displays that figure too.
  3. A hot spare is not included in the capacity, but it is counted in the total number of drives and in the usable share.
  4. Speed is given for random operations relative to a single drive: read ≈ number of drives, write ≈ number of drives / write penalty (RAID 1 and 10 — 2, RAID 5 and 50 — 4, RAID 6 and 60 — 6). A battery-backed controller cache smooths out writes but does not remove the penalty.
  5. Rebuild time is an estimate for one drive under a working load: HDD 50–120 MB/s, SSD 200–500 MB/s. The actual time depends on the controller, the rebuild priority and the load.

RAID levels compared

LevelMinimum drivesUsable capacityDrive failures toleratedWrite penaltyBest for
RAID 02n × drive01temporary data, cache, video editing
RAID 121 drive12OS boot volume, small servers
RAID 53(n − 1) × drive14file servers on SSDs and small SAS drives
RAID 64(n − 2) × drive26archives, backup, video surveillance on large HDDs
RAID 104n / 2 × drive1 (up to n / 2)2databases, 1C, virtualization
RAID 506(n − groups) × drive1 per group4large arrays where speed matters
RAID 608(n − 2 × groups) × drive2 per group6large archives and storage systems with 12+ drives

Questions and answers

How much space does RAID 5 give with 4 drives of 4 TB each?

One drive goes to parity: (4 − 1) × 4 = 12 TB. Windows will show about 10.9 TiB because it counts in TiB. For HDDs of this size, RAID 6 is safer: the same 4 drives give 8 TB, but the array survives a second failure during a rebuild.

Why does Windows show less than the capacity of the drives?

Manufacturers count 1 TB = 10¹² bytes, while Windows and Linux count 2⁴⁰ bytes (TiB) — a difference of about 9%. The controller also takes a little space for the array’s service data.

What should I choose for 1C, databases and virtualization?

RAID 10: its write penalty is 2, against 4 for RAID 5 and 6 for RAID 6, and a rebuild is a simple copy from the mirror. RAID 5 on SSDs suits file servers that are mostly read. Ready-made configurations are in the Server for 1C section.

Do I need a hot spare?

With 6 or more drives, yes. The controller starts the rebuild right after a failure without waiting for a drive replacement. While a rebuild is running, RAID 5 and RAID 10 have no safety margin, so the sooner it starts, the better.

Does RAID replace backups?

No. RAID protects against a drive failure, but not against deleted files, ransomware, controller failure or fire. You need a copy on another device — for example, on a backup server.

Which RAID levels does my server’s controller support?

It depends on the controller model: see the PERC and Smart Array reference. Suitable controllers with prices are in the RAID controllers section.