Skip to content

Dear customers! Please send orders and inquiries to [email protected] or to Telegram @servix_uz instead of calling by phone: due to the high workload, the operator cannot answer all incoming calls.

Servix

Dell PowerEdge 16G

Dell PowerEdge R760 — configurations and prices

Dual-socket 2U on 4th Gen Xeon Scalable and DDR5.

DELL R760 12LFF server (2×Xeon Silver 4410Y, 32GB)

At a glance.

2U

Chassisrack

2 sockets

Processors4th and 5th Gen Intel Xeon Scalable

8 TB

Memory, maximumDDR5, 32 slots

up to 24 SFF

Drive baysor 12 LFF

iDRAC 9

Remote management

About the R760

Dell PowerEdge R760 is a dual-socket 2U rack server by Dell (16G). Remote management: iDRAC 9.

Servix offers 2 R760 configurations. Prices on request; all new. Made to order in 2–⁠3 weeks; price and lead time are confirmed in an invoice with 12 % VAT.

More models in Dell PowerEdge servers; by use case: How to choose a Dell PowerEdge, Server for 1C, Virtualization server.

Inside the ready-made configurations

Ready-made R760 builds differ in processors, memory capacity, RAID controller and drive cage.

  • Processors: 2× Xeon Silver 4410Y (12 cores each).
  • RAM: 32 GB, DDR5 RDIMM.
  • Drive cage: 12 LFF — 1 build, 8 SFF — 1 build.
  • Drives: none in the ready-made builds (noHDD); the bays are free for your drives.
  • RAID controller: Dell PERC H755.
  • Power supplies: 2× 1100 W.
  • Networking: 2 port 1Gb/s.

R760 specifications

Form factor
Rack, 2U
Processors
2× Intel Xeon Silver 4410Y (12 cores / 24 threads, 2.00 GHz, turbo up to 3.90 GHz, 30 MB cache, TDP 150 W)
Expansion
PCIe Gen5 risers, up to eight expansion slots
Management
iDRAC9 with a dedicated network port, OpenManage

R760 configurations and prices

2 configurations, by price. Click a configuration for its specifications and cart. All items are made to order, 2–⁠3 weeks.

ConfigurationProcessorMemoryRAIDConditionPrice
12 LFF2× Xeon Silver 4410Y32 GB DDR5Dell PERC H755NewOn request
8 SFF2× Xeon Silver 4410Y32 GB DDR5Dell PERC H755NewOn request

Choosing your R760 configuration

SFF or LFF? SFF: 2.5″ bays, more drives per chassis, SSDs and fast SAS drives for databases and virtualization. LFF: 3.5″ bays, high-capacity HDDs for file storage, archives and backups.

Ready-made builds have 32 GB of memory; the platform takes up to 8 TB, so memory can be added later.

Need another configuration? Click “Request a quote”: we will match processors, memory and drives to your workload and send a proposal.

R760 and related models

Differences based on catalog data:

  • Dell PowerEdge R750: generation 15G vs 16G; 5 configurations from 44,000,000 UZS.
  • Dell PowerEdge R750xs: generation 15G vs 16G, memory up to 1 TB vs up to 8 TB; 3 configurations from 49,653,000 UZS.
  • Dell PowerEdge XE9680: chassis 6U vs 2U, memory up to 4 TB vs up to 8 TB; 1 configuration from 1,996,383,000 UZS.

How to order

Order from the table via the cart or click “Request a quote”: a manager confirms the configuration, price and lead time.

Payment by bank transfer, invoice with 12 % VAT. Free delivery in Tashkent; other regions of Uzbekistan are billed by address and weight as a separate invoice line. Installation and support: integration partner KP Solutions.

Dell PowerEdge R760 review: what workloads it suits and how to choose a configuration

What the R760 is bought for

The R760 is Dell's mainstream dual-processor 2U server of the 16th generation. Compared with its predecessors, it moves to DDR5, PCIe 5.0 and SAS 24 Gbps drives, and fourth-generation (Sapphire Rapids) or fifth-generation (Emerald Rapids) Xeon Scalable processors give up to 64 cores per socket. It is bought with workload growth in mind, not for a “here and now” task.

  • Main virtualization host. Consolidating dozens of VMs on two or three servers: up to 128 cores and up to 8 TB of memory per server.
  • DBMS and analytics. NVMe Gen5 in EDSFF E3.S bays and memory at up to 5600 MT/s.
  • VDI and AI inference. Up to two double-width 350 W GPUs and up to six single-slot 75 W GPUs.
  • 100GbE networking and DPU. OCP 3.0 cards up to 2 × 100GbE and a separate MIC card for connecting a DPU.
  • High-capacity storage. 12 × 3.5″ for large HDDs — this is how the R760 12LFFbuild is configured, while the 8SFF version is designed for SSDs.

The R760 is overkill for a file server with a few HDDs or for a single 1C server in a small office: such tasks are covered by previous generations. It will not be enough if you need more than 64 cores per processor or memory faster than 5600 MT/s — that is the next generation, the R770.

R760 platform

Processors. Two 4th Gen Xeon Scalable (up to 56 cores) or Xeon Max, or two 5th Gen Xeon (up to 64 cores). TDP up to 350 W, each processor has 80 PCIe 5.0 lanes. An important nuance: Dell produces the R760 with two system board variants. The MS (mainstream) board supports processors with TDP below 250 W; models from 250 W require the MAX board. Xeon Max 9480 and 9470, as well as 8470Q and 6458Q, are supported only with liquid cooling.

Memory. 32 DDR5 RDIMM slots — eight channels per processor, two modules per channel. Modules from 16 to 256 GB are supported, maximum 8 TB. With one module per channel, memory runs at 4800 MT/s with 4th Gen processors and at 5600 MT/s with 5th Gen; with two modules, at 4400 MT/s. The processor model also sets the ceiling: for the Silver 4410Y it is 4000 MT/s, for Gold 54xx 4400, for Gold 64xx and Platinum 84xx 4800 MT/s; in the 5th generation most Gold 65xx give 5200 MT/s, the top Platinum 85xx 5600 MT/s.

Drives. The front drive cage is 12 × 3.5″ SAS/SATA, 2.5″ for 8, 16 or 24 SAS/SATA/NVMe drives, or 16 × EDSFF E3.S with NVMe Gen5; at the rear there are two or four 2.5″ bays or four E3.S. The cages are designed for SAS4, i.e. 24 Gbps. Two restrictions from the documentation: Dell does not support Tri-Mode, where SAS, SATA and NVMe sit on one controller, and universal bays provide hardware RAID only for SAS/SATA — NVMe drives in them are connected directly to the processor.

RAID and boot. The entry-level H355 provides RAID 0, 1 and 10 without cache; the H755 and the H755N for NVMe have 8 GB of battery-backed cache; the top model is the PERC 12 H965i, the external one is the H965e. The HBA355i and HBA465i work without RAID; software RAID is the S160. For the OS — BOSS-N1: two M.2 NVMe drives with hardware RAID.

Network and expansion. The LOM module with two 1GbE ports and the OCP 3.0 slot are both options: you can install one, the other, or both. OCP cards: 4 × 1GbE, 2 or 4 × 10GbE, 2 or 4 × 25GbE, 2 × 100GbE. On the MS board the OCP slot runs in x8 mode. Up to eight PCIe slots, some of them Gen5.

Power and cooling. Power supplies from 700 to 3200 W: most are 100–⁠240 or 200–⁠240 V, the Titanium models of 1400 and 3200 W are 277 V, and there is a 1100 W unit for −48…−60 V DC. Direct liquid cooling (DLC) is a rack-level solution: it requires manifolds in the rack and a coolant distribution unit (CDU).

Management and security. iDRAC9 with the Redfish REST API, iDRAC Direct and Quick Sync 2. According to Dell's license table, Express is the default on 600-series servers and above. Enterprise adds the virtual console and AD/LDAP integration; Datacenter adds streaming telemetry, Thermal Manage and automated certificate management. Security features include Silicon Root of Trust, component authenticity verification (Secured Component Verification) and encryption on SED drives with local or external key management.

Dimensions. Chassis depth is 758.29 mm without the bezel; with a fully populated drive cage the server weighs up to 36.1 kg.

How the R760 differs from its neighbors

The closest neighbor is the previous R750. Key differences according to Dell's technical guides:

What we compare

R750 (15G)

R760 (16G)

Xeon Scalable generation

3rd, up to 40 cores

4th and 5th, up to 64 cores

Maximum TDP

270 W

350 W

Module types

DDR4 RDIMM and LRDIMM, Optane PMem 200

DDR5 RDIMM only

Memory speed

3200 MT/s with 1 and 2 modules per channel

4800 or 5600 MT/s with one module, 4400 with two

PCIe, lane speed

Gen4, 16 GT/s

Gen5, 32 GT/s

Drive interface

SAS 12 Gbps, NVMe Gen3/4

SAS 24 Gbps, NVMe up to Gen5 in E3.S bays

Boot module

BOSS-S1 or BOSS-S2

BOSS-N1 on M.2 NVMe

Top RAID controller

PERC 11 H755

PERC 12 H965i

Most powerful power supply

2800 W

3200 W

R760 or R750. R750 remains a sensible choice if DDR4 and 40 cores per processor are enough and NVMe Gen4 covers your drive needs. The R760 is justified when the server is bought for the long term, or when you need 100GbE, NVMe Gen5, fast DDR5 memory or processors with more than 40 cores.

Two generations back — R740. 14G with DDR4-2933, PCIe 3.0 and a maximum of 28 cores per processor is still fine for files and backups, but for new virtualization the gap with the R760 is too large. Refurbished R740 servers are a sensible buy for a well-defined workload with no growth plans.

Next generation — R770. Intel Xeon 6 with performance or efficient cores: up to 86 P-cores or 144 E-cores per processor, DDR5 up to 6400 MT/s. Details are in the R770 review.

1U version — R660. The same processors and 32 DDR5 slots, but a drive cage of no more than 10 × 2.5″ or 16 × E3.S and at most three PCIe slots. The R660 is chosen when every rack unit counts and there are only a few drives and cards; a comparison is in the article on the R650 and R660.

R760 configuration: where to start

Processors and licenses. Windows Server requires licensing all physical cores, but with no fewer than eight licenses per processor and sixteen per server; Standard covers two VMs on a fully licensed host, Datacenter has no limit on the number of VMs. In a VMware subscription, each processor counts as at least 16 cores. Hence the choice:

  • Gold 6434 (8 cores, 3.7 GHz) — a high-frequency option for 1C and SQL Server on Windows;
  • Gold 6442Y (24 cores, 2.6 GHz, 225 W) — a balanced option for VMware, fits the MS board;
  • Gold 6430 (32 cores, 2.1 GHz, 270 W) — dense virtualization, but only on the MAX board;
  • Silver 4410Y (12 cores, 2.0 GHz, 150 W), as in the ready-made builds, is good for storage and backup, but limits memory to 4000 MT/s.

Memory. Eight modules per processor, one per channel, give the maximum frequency. Sixteen modules per processor double the capacity but lower the frequency to 4400 MT/s. With four modules per processor, half the channels are empty — this configuration is not recommended. Example for virtualization: 16 × 32 GB = 512 GB at 4800 MT/s with Gold 64xx. How to count channels and ranks is covered in the article on server memory.

Drives and RAID. RAID 5 and 6 — on the H755 or H965i with cache; keep the H355 for a mirror or RAID 10 without high write requirements. Connect NVMe for software-defined storage directly; hardware RAID on NVMe requires the NVMe RAID version of the drive cage and a controller such as the H755N. Usable array capacity is in the RAID calculator.

Network. OCP 2 × 25GbE is the standard for virtualization hosts, 2 × 100GbE for storage and clusters. On the MS board the OCP slot runs at x8, so 100GbE is better installed in a PCIe slot.

Power. Install power supplies in pairs of the same wattage: if they do not match, Dell enables only the more powerful one. For GPU configurations, plan for 2400–⁠2800 W units.

Task

Processors

Memory

Drives

Controller and network

1C, SQL Server

2 × Gold 6434

16 × 32 GB

8 × 2,5″ NVMe

H755N, OCP 2 × 25GbE

VMware cluster of 2–⁠3 hosts

2 × Gold 6442Y

16 × 64 GB

BOSS-N1 for ESXi, 8–⁠16 × 2.5″ SSD

H755 or HBA355i, 2 × 25GbE

Storage and backups

2 × Silver 4410Y

16 × 16 GB

12 × 3,5″ HDD, RAID 6

H755, 2 × 10GbE

GPU and inference

2 × Gold 6430, MAX board

16 × 64 GB

8 × 2,5″ NVMe

2 × 100GbE, 2400–⁠2800 W power supplies

Sizing for a specific number of users is on the pages server for 1C and server for virtualization.

Refurbished R760: what to check

  • MS or MAX system board. It determines which processors can be installed in an upgrade: models from 250 W do not work on the MS board.
  • Processor generation. With 4th Gen processors, 5600 MT/s modules will run at 4800 — keep this in mind when buying additional memory.
  • iDRAC license. The remote console requires Enterprise; check the license level in the iDRAC itself, not in the listing description.
  • Firmware for BIOS, iDRAC, PERC and BOSS-N1 — update it before putting the server into service.
  • The H755 cache battery must be healthy, otherwise the controller works without write-back.
  • Power supplies of the same wattage, otherwise there is no redundancy.
  • Drive trays and rails. 2.5″ and E3.S trays are different — check that the kit matches your drive cage.

When a refurbished server is justified and when a new one is better is covered in the article “Refurbished or new server”.

Related models.

16G · 2U · 2 sockets

R760

Dual-socket 2U on 4th Gen Xeon Scalable and DDR5.

15G · 2U · 2 sockets

R750

Dual-socket 2U: up to 24 drives of 2.5″, up to 32 DDR4 slots.

from 44,000,000 UZS5 configurations · 3 refurbished

Refurbished · 15G · 2U · 2 sockets

R750xs

Dell PowerEdge

from 49,653,000 UZS3 configurations · all refurbished

Refurbished · 6U · 2 sockets

XE9680

Dell PowerEdge

from 1,996,383,000 UZS1 configuration · refurbished

Questions and answers

What does Dell PowerEdge R760 cost?

Price on request: click “Request a quote”.

R760: new or refurbished?

Both configurations in the catalog are new.

What is the R760 lead time?

Made to order, 2–3 weeks; the exact lead time and price are confirmed in the invoice.

What is the R760 warranty?

Warranty: 12 months on all equipment (new, refurbished and used), serviced by Servix.

Can the R760 be configured for my workload?

Click “Request a quote” and describe your task: we will match a configuration to your workload and budget.

How does R760 differ from R750?

Per catalog data (R750 vs R760): generation 15G vs 16G.

Need a quote?

Leave a phone number or Telegram — we will send the configuration, price in UZS and lead time. Invoice with 12% VAT.

Installation and support — KP Solutions

Need more than hardware? Our integrator partner will install your servers and network, configure them and provide ongoing support.

Go to the KP Solutions website ↗